@@ -42,12 +42,8 @@ static void tmp105_interrupt_update(TMP105State *s)
static void tmp105_alarm_update(TMP105State *s, bool one_shot)
{
- if (FIELD_EX8(s->config, CONFIG, SHUTDOWN_MODE)) {
- if (one_shot) {
- s->config = FIELD_DP8(s->config, CONFIG, ONE_SHOT, 0);
- } else {
- return;
- }
+ if (FIELD_EX8(s->config, CONFIG, SHUTDOWN_MODE) && !one_shot) {
+ return;
}
if (FIELD_EX8(s->config, CONFIG, THERMOSTAT_MODE)) {
@@ -166,7 +162,7 @@ static void tmp105_write(TMP105State *s)
if (FIELD_EX8(s->buf[0] & ~s->config, CONFIG, SHUTDOWN_MODE)) {
printf("%s: TMP105 shutdown\n", __func__);
}
- s->config = s->buf[0];
+ s->config = FIELD_DP8(s->buf[0], CONFIG, ONE_SHOT, 0);
s->faults = tmp105_faultq[FIELD_EX8(s->config, CONFIG, FAULT_QUEUE)];
tmp105_alarm_update(s, FIELD_EX8(s->buf[0], CONFIG, ONE_SHOT));
break;