@@ -864,6 +864,7 @@ struct sysib_322 {
#define SK_F (0x1 << 3)
#define SK_ACC_MASK (0xf << 4)
+/* SIGP order codes */
#define SIGP_SENSE 0x01
#define SIGP_EXTERNAL_CALL 0x02
#define SIGP_EMERGENCY 0x03
@@ -877,7 +878,13 @@ struct sysib_322 {
#define SIGP_STORE_STATUS_ADDR 0x0e
#define SIGP_SET_ARCH 0x12
-/* cpu status bits */
+/* SIGP condition codes */
+#define SIGP_CC_ORDER_CODE_ACCEPTED 0
+#define SIGP_CC_STATUS_STORED 1
+#define SIGP_CC_BUSY 2
+#define SIGP_CC_NOT_OPERATIONAL 3
+
+/* SIGP status bits */
#define SIGP_STAT_EQUIPMENT_CHECK 0x80000000UL
#define SIGP_STAT_INCORRECT_STATE 0x00000200UL
#define SIGP_STAT_INVALID_PARAMETER 0x00000100UL
@@ -1178,37 +1178,37 @@ static int handle_sigp(S390CPU *cpu, struct kvm_run *run, uint8_t ipa1)
cpu_addr = env->regs[ipa1 & 0x0f];
target_cpu = s390_cpu_addr2state(cpu_addr);
if (target_cpu == NULL) {
- cc = 3; /* not operational */
+ cc = SIGP_CC_NOT_OPERATIONAL;
goto out;
}
switch (order_code) {
case SIGP_START:
run_on_cpu(CPU(target_cpu), sigp_cpu_start, CPU(target_cpu));
- cc = 0;
+ cc = SIGP_CC_ORDER_CODE_ACCEPTED;
break;
case SIGP_RESTART:
run_on_cpu(CPU(target_cpu), sigp_cpu_restart, CPU(target_cpu));
- cc = 0;
+ cc = SIGP_CC_ORDER_CODE_ACCEPTED;
break;
case SIGP_SET_ARCH:
*statusreg &= 0xffffffff00000000UL;
*statusreg |= SIGP_STAT_INVALID_PARAMETER;
- cc = 1; /* status stored */
+ cc = SIGP_CC_STATUS_STORED;
break;
case SIGP_INITIAL_CPU_RESET:
run_on_cpu(CPU(target_cpu), sigp_initial_cpu_reset, CPU(target_cpu));
- cc = 0;
+ cc = SIGP_CC_ORDER_CODE_ACCEPTED;
break;
case SIGP_CPU_RESET:
run_on_cpu(CPU(target_cpu), sigp_cpu_reset, CPU(target_cpu));
- cc = 0;
+ cc = SIGP_CC_ORDER_CODE_ACCEPTED;
break;
default:
DPRINTF("KVM: unknown SIGP: 0x%x\n", order_code);
*statusreg &= 0xffffffff00000000UL;
*statusreg |= SIGP_STAT_INVALID_ORDER;
- cc = 1; /* status stored */
+ cc = SIGP_CC_STATUS_STORED;
break;
}
@@ -456,7 +456,7 @@ uint32_t HELPER(stsi)(CPUS390XState *env, uint64_t a0,
uint32_t HELPER(sigp)(CPUS390XState *env, uint64_t order_code, uint32_t r1,
uint64_t cpu_addr)
{
- int cc = 0;
+ int cc = SIGP_CC_ORDER_CODE_ACCEPTED;
HELPER_LOG("%s: %016" PRIx64 " %08x %016" PRIx64 "\n",
__func__, order_code, r1, cpu_addr);
@@ -490,7 +490,7 @@ uint32_t HELPER(sigp)(CPUS390XState *env, uint64_t order_code, uint32_t r1,
default:
/* unknown sigp */
fprintf(stderr, "XXX unknown sigp: 0x%" PRIx64 "\n", order_code);
- cc = 3;
+ cc = SIGP_CC_NOT_OPERATIONAL;
}
return cc;