On Wed, Aug 14, 2019 at 1:18 AM Sagar Shrikant Kadam <sagar.kadam@sifive.com> wrote: > > Use the SPI controller in FU540-C000 soc in one bit mode, rather than using > spi-tx-bus-width and spi-rx-bus-width passed from the device tree. > > This patch handles a case where controller mode in format register (0x40) > is configured as per the width specified in the dt-node of the slave > device. For instance if spi-tx-bus-width and spi-rx-bus-width in the flash > device node in dt is set to 4 bit mode, the controller gets configured in > QUAD mode, whereas the spi nor scan tries to read the JEDEC ID with the > reg_proto set to SNOR_PROTO_1_1_1 and fails. > > Signed-off-by: Sagar Shrikant Kadam <sagar.kadam@sifive.com> > --- > drivers/spi/spi-sifive.c | 7 +------ > 1 file changed, 1 insertion(+), 6 deletions(-) > > diff --git a/drivers/spi/spi-sifive.c b/drivers/spi/spi-sifive.c > index 969bd4b..7cf3ea4 100644 > --- a/drivers/spi/spi-sifive.c > +++ b/drivers/spi/spi-sifive.c > @@ -146,12 +146,7 @@ static void sifive_spi_prep_transfer(struct sifive_spi *spi, > > /* Number of wires ? */ > cr &= ~SIFIVE_SPI_FMT_PROTO_MASK; > - if ((slave->mode & SPI_TX_QUAD) || (slave->mode & SPI_RX_QUAD)) > - cr |= SIFIVE_SPI_FMT_PROTO_QUAD; > - else if ((slave->mode & SPI_TX_DUAL) || (slave->mode & SPI_RX_DUAL)) > - cr |= SIFIVE_SPI_FMT_PROTO_DUAL; > - else > - cr |= SIFIVE_SPI_FMT_PROTO_SINGLE; > + cr |= SIFIVE_SPI_FMT_PROTO_SINGLE; This change makes the SPI controller no longer a QSPI any more. Why? I actually have a local spi-nor version that works on HiFive Unleashed without this changes at all and JEDEC ID can be read correctly. > > /* SPI direction in/out ? */ > cr &= ~SIFIVE_SPI_FMT_DIR; > -- Regards, Bin
diff --git a/drivers/spi/spi-sifive.c b/drivers/spi/spi-sifive.c index 969bd4b..7cf3ea4 100644 --- a/drivers/spi/spi-sifive.c +++ b/drivers/spi/spi-sifive.c @@ -146,12 +146,7 @@ static void sifive_spi_prep_transfer(struct sifive_spi *spi, /* Number of wires ? */ cr &= ~SIFIVE_SPI_FMT_PROTO_MASK; - if ((slave->mode & SPI_TX_QUAD) || (slave->mode & SPI_RX_QUAD)) - cr |= SIFIVE_SPI_FMT_PROTO_QUAD; - else if ((slave->mode & SPI_TX_DUAL) || (slave->mode & SPI_RX_DUAL)) - cr |= SIFIVE_SPI_FMT_PROTO_DUAL; - else - cr |= SIFIVE_SPI_FMT_PROTO_SINGLE; + cr |= SIFIVE_SPI_FMT_PROTO_SINGLE; /* SPI direction in/out ? */ cr &= ~SIFIVE_SPI_FMT_DIR;
Use the SPI controller in FU540-C000 soc in one bit mode, rather than using spi-tx-bus-width and spi-rx-bus-width passed from the device tree. This patch handles a case where controller mode in format register (0x40) is configured as per the width specified in the dt-node of the slave device. For instance if spi-tx-bus-width and spi-rx-bus-width in the flash device node in dt is set to 4 bit mode, the controller gets configured in QUAD mode, whereas the spi nor scan tries to read the JEDEC ID with the reg_proto set to SNOR_PROTO_1_1_1 and fails. Signed-off-by: Sagar Shrikant Kadam <sagar.kadam@sifive.com> --- drivers/spi/spi-sifive.c | 7 +------ 1 file changed, 1 insertion(+), 6 deletions(-)