@@ -2642,17 +2642,17 @@ binding_handle_ovs_interface_changes(struct binding_ctx_in *b_ctx_in,
const struct ovsrec_interface *iface_rec;
OVSREC_INTERFACE_TABLE_FOR_EACH_TRACKED (iface_rec,
b_ctx_in->iface_table) {
- if (!is_iface_vif(iface_rec)) {
- /* Right now we are not handling ovs_interface changes of
- * other types. This can be enhanced to handle of
- * types - patch and tunnel. */
+ const char *iface_id = smap_get(&iface_rec->external_ids, "iface-id");
+ const char *old_iface_id = smap_get(b_ctx_out->local_iface_ids,
+ iface_rec->name);
+ if (!iface_id && !old_iface_id && !is_iface_vif(iface_rec)) {
+ /* Right now we are not handling ovs_interface changes if the
+ * interface doesn't have iface-id or didn't have it
+ * previously. */
handled = false;
break;
}
- const char *iface_id = smap_get(&iface_rec->external_ids, "iface-id");
- const char *old_iface_id = smap_get(b_ctx_out->local_iface_ids,
- iface_rec->name);
const char *cleared_iface_id = NULL;
if (!ovsrec_interface_is_deleted(iface_rec)) {
int64_t ofport = iface_rec->n_ofport ? *iface_rec->ofport : 0;
@@ -3299,3 +3299,60 @@ wait_ovs_ct_limit_count 0
OVN_CLEANUP([hv1])
AT_CLEANUP
])
+
+AT_SETUP([ovn-controller - I-P different port types])
+AT_KEYWORDS([ovn])
+ovn_start
+
+net_add n1
+sim_add hv1
+ovs-vsctl add-br br-phys
+ovn_attach n1 br-phys 192.168.0.20
+
+check ovn-nbctl ls-add ls0
+check ovn-nbctl lsp-add ls0 vif
+
+ovn-appctl inc-engine/clear-stats
+
+ovs-vsctl -- add-port br-int vif -- \
+ set Interface vif external-ids:iface-id=vif
+wait_row_count Port_Binding 1 logical_port="vif" up=true
+
+ovs-vsctl del-port br-int vif
+wait_row_count Port_Binding 1 logical_port="vif" up=false
+
+ovs-vsctl add-port br-int vif -- \
+ set Interface vif type=dummy -- \
+ set Interface vif external-ids:iface-id=vif
+wait_row_count Port_Binding 1 logical_port="vif" up=true
+
+ovs-vsctl del-port br-int vif
+wait_row_count Port_Binding 1 logical_port="vif" up=false
+
+ovs-vsctl add-port br-int vif -- \
+ set Interface vif type=geneve -- \
+ set Interface vif options:remote_ip=1.1.1.1 external-ids:iface-id=vif
+wait_row_count Port_Binding 1 logical_port="vif" up=true
+
+ovs-vsctl del-port br-int vif
+wait_row_count Port_Binding 1 logical_port="vif" up=false
+
+# Make sure that setting iface in two different transaction doesn't
+# cause recompute.
+ovs-vsctl add-port br-int vif
+ovs-vsctl set Interface vif external-ids:iface-id=vif
+wait_row_count Port_Binding 1 logical_port="vif" up=true
+
+ovs-vsctl del-port br-int vif
+wait_row_count Port_Binding 1 logical_port="vif" up=false
+
+AT_CHECK([ovn-appctl inc-engine/show-stats runtime_data |\
+ sed "s/- compute:\s\+[[0-9]]\+/- compute: ??/"], [0], [dnl
+Node: runtime_data
+- recompute: 0
+- compute: ??
+- cancel: 0
+])
+
+OVN_CLEANUP([hv1])