On Thu, Nov 07, 2013 at 05:53:13PM +0100, Florent Fourcot wrote: > If the last RFC 6437 does not give any constraints > for lifetime of flow labels, the previous RFC 3697 > spoke of a minimum of 120 seconds between > reattribution of a flow label. > > The maximum linger is currently set to 60 seconds > and does not allow this configuration without > CAP_NET_ADMIN right. > > This patch increase the maximum linger to 150 > seconds, allowing more flexibility to standard > users. Acked-by: Hannes Frederic Sowa <hannes@stressinduktion.org> -- To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
From: Florent Fourcot <florent.fourcot@enst-bretagne.fr> Date: Thu, 7 Nov 2013 17:53:13 +0100 > If the last RFC 6437 does not give any constraints > for lifetime of flow labels, the previous RFC 3697 > spoke of a minimum of 120 seconds between > reattribution of a flow label. > > The maximum linger is currently set to 60 seconds > and does not allow this configuration without > CAP_NET_ADMIN right. > > This patch increase the maximum linger to 150 > seconds, allowing more flexibility to standard > users. > > Signed-off-by: Florent Fourcot <florent.fourcot@enst-bretagne.fr> Applied. -- To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
diff --git a/net/ipv6/ip6_flowlabel.c b/net/ipv6/ip6_flowlabel.c index 4a06ed0..5f10b0d 100644 --- a/net/ipv6/ip6_flowlabel.c +++ b/net/ipv6/ip6_flowlabel.c @@ -41,7 +41,7 @@ #define FL_MIN_LINGER 6 /* Minimal linger. It is set to 6sec specified in old IPv6 RFC. Well, it was reasonable value. */ -#define FL_MAX_LINGER 60 /* Maximal linger timeout */ +#define FL_MAX_LINGER 150 /* Maximal linger timeout */ /* FL hash table */
If the last RFC 6437 does not give any constraints for lifetime of flow labels, the previous RFC 3697 spoke of a minimum of 120 seconds between reattribution of a flow label. The maximum linger is currently set to 60 seconds and does not allow this configuration without CAP_NET_ADMIN right. This patch increase the maximum linger to 150 seconds, allowing more flexibility to standard users. Signed-off-by: Florent Fourcot <florent.fourcot@enst-bretagne.fr> --- net/ipv6/ip6_flowlabel.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)