new file mode 100644
@@ -0,0 +1,57 @@
+Device tree configuration for PECI buses on the AST24XX and AST25XX SoCs.
+
+Required properties:
+- compatible : Should be "aspeed,ast2400-peci" or "aspeed,ast2500-peci"
+ - aspeed,ast2400-peci: ASPEED AST2400 family PECI
+ controller
+ - aspeed,ast2500-peci: ASPEED AST2500 family PECI
+ controller
+- reg : Should contain PECI controller registers location and
+ length.
+- #address-cells : Should be <1> required to define a client address.
+- #size-cells : Should be <0> required to define a client address.
+- interrupts : Should contain PECI controller interrupt.
+- clocks : Should contain clock source for PECI controller. Should
+ reference the external oscillator clock in the second
+ cell.
+- resets : Should contain phandle to reset controller with the reset
+ number in the second cell.
+- clock-frequency : Should contain the operation frequency of PECI controller
+ in units of Hz.
+ 187500 ~ 24000000
+
+Optional properties:
+- msg-timing : Message timing negotiation period. This value will
+ determine the period of message timing negotiation to be
+ issued by PECI controller. The unit of the programmed
+ value is four times of PECI clock period.
+ 0 ~ 255 (default: 1)
+- addr-timing : Address timing negotiation period. This value will
+ determine the period of address timing negotiation to be
+ issued by PECI controller. The unit of the programmed
+ value is four times of PECI clock period.
+ 0 ~ 255 (default: 1)
+- rd-sampling-point : Read sampling point selection. The whole period of a bit
+ time will be divided into 16 time frames. This value will
+ determine the time frame in which the controller will
+ sample PECI signal for data read back. Usually in the
+ middle of a bit time is the best.
+ 0 ~ 15 (default: 8)
+- cmd-timeout-ms : Command timeout in units of ms.
+ 1 ~ 60000 (default: 1000)
+
+Example:
+ peci0: peci-bus@0 {
+ compatible = "aspeed,ast2500-peci";
+ reg = <0x0 0x60>;
+ #address-cells = <1>;
+ #size-cells = <0>;
+ interrupts = <15>;
+ clocks = <&syscon ASPEED_CLK_GATE_REFCLK>;
+ resets = <&syscon ASPEED_RESET_PECI>;
+ clock-frequency = <24000000>;
+ msg-timing = <1>;
+ addr-timing = <1>;
+ rd-sampling-point = <8>;
+ cmd-timeout-ms = <1000>;
+ };