@@ -327,7 +327,8 @@ extern void _hurd_internal_post_signal (struct hurd_sigstate *ss,
struct machine_thread_all_state;
extern struct sigcontext *
-_hurd_setup_sighandler (struct hurd_sigstate *ss, __sighandler_t handler,
+_hurd_setup_sighandler (struct hurd_sigstate *ss, const struct sigaction *action,
+ __sighandler_t handler,
int signo, struct hurd_signal_detail *detail,
int rpc_wait, struct machine_thread_all_state *state);
@@ -624,6 +624,13 @@ post_signal (struct hurd_sigstate *ss,
enum { stop, ignore, core, term, handle } act;
int ss_suspended;
+ /* sigaction for preemptors */
+ struct sigaction preempt_sigaction = {
+ .sa_flags = SA_RESTART
+ };
+
+ struct sigaction *action;
+
/* Mark the signal as pending. */
void mark_pending (void)
{
@@ -780,12 +787,17 @@ post_signal (struct hurd_sigstate *ss,
/* Ignore the signal altogether. */
act = ignore;
else if (handler != SIG_ERR)
- /* Run the preemption-provided handler. */
- act = handle;
+ {
+ /* Run the preemption-provided handler. */
+ action = &preempt_sigaction;
+ act = handle;
+ }
else
{
/* No preemption. Do normal handling. */
+ action = & _hurd_sigstate_actions (ss) [signo];
+
if (!untraced && __sigismember (&_hurdsig_traced, signo))
{
/* We are being traced. Stop to tell the debugger of the signal. */
@@ -800,7 +812,7 @@ post_signal (struct hurd_sigstate *ss,
return NULL;
}
- handler = _hurd_sigstate_actions (ss) [signo].sa_handler;
+ handler = action->sa_handler;
if (handler == SIG_DFL)
/* Figure out the default action for this signal. */
@@ -1072,7 +1084,7 @@ post_signal (struct hurd_sigstate *ss,
/* Call the machine-dependent function to set the thread up
to run the signal handler, and preserve its old context. */
- scp = _hurd_setup_sighandler (ss, handler, signo, detail,
+ scp = _hurd_setup_sighandler (ss, action, handler, signo, detail,
wait_for_reply, &thread_state);
if (scp == NULL)
goto sigbomb;
@@ -1111,8 +1123,6 @@ post_signal (struct hurd_sigstate *ss,
}
}
- struct sigaction *action = & _hurd_sigstate_actions (ss) [signo];
-
/* Backdoor extra argument to signal handler. */
scp->sc_error = detail->error;
@@ -80,7 +80,8 @@ static void fill_ucontext (ucontext_t *uc, const struct sigcontext *sc)
}
struct sigcontext *
-_hurd_setup_sighandler (struct hurd_sigstate *ss, __sighandler_t handler,
+_hurd_setup_sighandler (struct hurd_sigstate *ss, const struct sigaction *action,
+ __sighandler_t handler,
int signo, struct hurd_signal_detail *detail,
volatile int rpc_wait,
struct machine_thread_all_state *state)
@@ -90,7 +91,6 @@ _hurd_setup_sighandler (struct hurd_sigstate *ss, __sighandler_t handler,
void firewall (void);
extern const void _hurd_intr_rpc_msg_cx_sp;
extern const void _hurd_intr_rpc_msg_sp_restored;
- const struct sigaction *action;
void *volatile sigsp;
struct sigcontext *scp;
struct
@@ -123,11 +123,6 @@ _hurd_setup_sighandler (struct hurd_sigstate *ss, __sighandler_t handler,
siginfo_t siginfo;
} *stackframe;
- /* sigaction for preemptors */
- static const struct sigaction legacy_sigaction = {
- .sa_flags = SA_RESTART
- };
-
if (ss->context)
{
/* We have a previous sigcontext that sigreturn was about
@@ -170,14 +165,6 @@ _hurd_setup_sighandler (struct hurd_sigstate *ss, __sighandler_t handler,
the SP on sigreturn. */
state->basic.uesp = state->basic.ecx;
- action = & _hurd_sigstate_actions (ss) [signo];
- if ( (action->sa_flags & SA_SIGINFO)
- && handler != (__sighandler_t) action->sa_sigaction
- || !(action->sa_flags & SA_SIGINFO)
- && handler != action->sa_handler)
- /* A signal preemptor took over, use legacy semantic. */
- action = &legacy_sigaction;
-
if ((action->sa_flags & SA_ONSTACK)
&& !(ss->sigaltstack.ss_flags & (SS_DISABLE|SS_ONSTACK)))
{