@@ -75,6 +75,13 @@ Sub-nodes:
same. Also the gpio phandle must refer to to the dlg,da9062-gpio device
other gpios are not allowed and make no sense.
+ - dlg,ena-sense-gpios : The GPIO reference which should be used by the
+ regulator to enable/disable the output. If the signal is active the
+ regulator is on else it is off. Attention: Sharing the same gpio for other
+ purposes or across multiple regulators is possible but the gpio settings
+ must be the same. Also the gpio phandle must refer to to the
+ dlg,da9062-gpio device other gpios are not allowed and make no sense.
+
- rtc : This node defines settings required for the Real-Time Clock associated
with the DA9062. There are currently no entries in this binding, however
compatible = "dlg,da9062-rtc" should be added if a node is created.
At the gpio-based regulator enable/disable documentation. This property can be applied to each subnode within the 'regulators' node so each regulator can be configured differently. Signed-off-by: Marco Felsch <m.felsch@pengutronix.de> --- Documentation/devicetree/bindings/mfd/da9062.txt | 7 +++++++ 1 file changed, 7 insertions(+)