On 29/03/2024 15:49:40+0530, Karthikeyan Krishnasamy wrote: > PORF flag is set during power reset and voltage drop below Vpor > data in rtc device is no longer valid if PORF flag is set > and software must reset to 0, in order to perform sanity > check on rtc data > > Signed-off-by: Karthikeyan Krishnasamy <karthikeyan@linumiz.com> > --- > drivers/rtc/rtc-rv3028.c | 7 +++++++ > 1 file changed, 7 insertions(+) > > diff --git a/drivers/rtc/rtc-rv3028.c b/drivers/rtc/rtc-rv3028.c > index 2f001c59c61d..e9699ff0c4e8 100644 > --- a/drivers/rtc/rtc-rv3028.c > +++ b/drivers/rtc/rtc-rv3028.c > @@ -951,6 +951,13 @@ static int rv3028_probe(struct i2c_client *client) > if (ret < 0) > return ret; > > + if (status & RV3028_STATUS_PORF) { > + ret = regmap_update_bits(rv3028->regmap, RV3028_STATUS, > + RV3028_STATUS_PORF, 0); > + if (ret < 0) > + return ret; > + } > + This breaks the workflow, you must set the time to reset PORF. > if (status & RV3028_STATUS_AF) > dev_warn(&client->dev, "An alarm may have been missed.\n"); > > -- > 2.34.1 >
Agreed. Thanks for clarification. Regards, Karthikeyan Krishnasamy On 3/29/24 15:58, Alexandre Belloni wrote: > On 29/03/2024 15:49:40+0530, Karthikeyan Krishnasamy wrote: >> PORF flag is set during power reset and voltage drop below Vpor >> data in rtc device is no longer valid if PORF flag is set >> and software must reset to 0, in order to perform sanity >> check on rtc data >> >> Signed-off-by: Karthikeyan Krishnasamy <karthikeyan@linumiz.com> >> --- >> drivers/rtc/rtc-rv3028.c | 7 +++++++ >> 1 file changed, 7 insertions(+) >> >> diff --git a/drivers/rtc/rtc-rv3028.c b/drivers/rtc/rtc-rv3028.c >> index 2f001c59c61d..e9699ff0c4e8 100644 >> --- a/drivers/rtc/rtc-rv3028.c >> +++ b/drivers/rtc/rtc-rv3028.c >> @@ -951,6 +951,13 @@ static int rv3028_probe(struct i2c_client *client) >> if (ret < 0) >> return ret; >> >> + if (status & RV3028_STATUS_PORF) { >> + ret = regmap_update_bits(rv3028->regmap, RV3028_STATUS, >> + RV3028_STATUS_PORF, 0); >> + if (ret < 0) >> + return ret; >> + } >> + > > This breaks the workflow, you must set the time to reset PORF. > >> if (status & RV3028_STATUS_AF) >> dev_warn(&client->dev, "An alarm may have been missed.\n"); >> >> -- >> 2.34.1 >> >
diff --git a/drivers/rtc/rtc-rv3028.c b/drivers/rtc/rtc-rv3028.c index 2f001c59c61d..e9699ff0c4e8 100644 --- a/drivers/rtc/rtc-rv3028.c +++ b/drivers/rtc/rtc-rv3028.c @@ -951,6 +951,13 @@ static int rv3028_probe(struct i2c_client *client) if (ret < 0) return ret; + if (status & RV3028_STATUS_PORF) { + ret = regmap_update_bits(rv3028->regmap, RV3028_STATUS, + RV3028_STATUS_PORF, 0); + if (ret < 0) + return ret; + } + if (status & RV3028_STATUS_AF) dev_warn(&client->dev, "An alarm may have been missed.\n");
PORF flag is set during power reset and voltage drop below Vpor data in rtc device is no longer valid if PORF flag is set and software must reset to 0, in order to perform sanity check on rtc data Signed-off-by: Karthikeyan Krishnasamy <karthikeyan@linumiz.com> --- drivers/rtc/rtc-rv3028.c | 7 +++++++ 1 file changed, 7 insertions(+)