diff mbox

[V3] dt: net: enhance DWC EQoS binding to support Tegra186

Message ID 20160901190216.5643-1-swarren@wwwdotorg.org
State Deferred
Headers show

Commit Message

Stephen Warren Sept. 1, 2016, 7:02 p.m. UTC
From: Stephen Warren <swarren@nvidia.com>

The Synopsys DWC EQoS is a configurable IP block which supports multiple
options for bus type, clocking and reset structure, and feature list.
Extend the DT binding to define a "compatible value" for the configuration
contained in NVIDIA's Tegra186 SoC, and define some new properties and
list property entries required by that configuration.

Signed-off-by: Stephen Warren <swarren@nvidia.com>
---
v3:
* Document legacy clock-names entries separately, and make it obvious
  they're deprecated.
* Reword the description of the "rx" clock to better describe the HW.
* Add some extra guidance for future extensions of the binding to cover
  configurations where additional RX clocks are required.
* Explicitly document the list of clocks and resets for every compatible
  value; don't miss any out.
v2:
* Add an explicit compatible value for the Axis SoC's version of the EQOS
  IP; this allows the driver to handle any SoC-specific integration quirks
  that are required, rather than only knowing about the IP block in
  isolation. This is good general DT practice. The existing value is still
  documented to support existing DTs.
* Reworked the list of clocks the binding requires:
  - Combined "tx" and "phy_ref_clk"; for GMII/RGMII configurations, these
    are the same thing.
  - Added extra description to the "rx" and "tx" clocks, to make it clear
    exactly which HW clock they represent.
  - Made the new "tx" and "slave_bus" names more prominent than the
    original "phy_ref_clk" and "apb_pclk". The new names are more generic
    and should work for any enhanced version of the binding (e.g. to
    support additional PHY types). New compatible values will hopefully
    choose to require the new names.
* Added a couple extra clocks to the list that may need to be supported in
  future binding revisions.
* Fixed a typo; "clocks" -> "resets".
---
 .../bindings/net/snps,dwc-qos-ethernet.txt         | 99 +++++++++++++++++++++-
 1 file changed, 95 insertions(+), 4 deletions(-)

Comments

Lars Persson Sept. 2, 2016, 7:56 a.m. UTC | #1
On 09/01/2016 09:02 PM, Stephen Warren wrote:
> From: Stephen Warren <swarren@nvidia.com>
>
> The Synopsys DWC EQoS is a configurable IP block which supports multiple
> options for bus type, clocking and reset structure, and feature list.
> Extend the DT binding to define a "compatible value" for the configuration
> contained in NVIDIA's Tegra186 SoC, and define some new properties and
> list property entries required by that configuration.
>
> Signed-off-by: Stephen Warren <swarren@nvidia.com>
> ---
> v3:
> * Document legacy clock-names entries separately, and make it obvious
>   they're deprecated.
> * Reword the description of the "rx" clock to better describe the HW.
> * Add some extra guidance for future extensions of the binding to cover
>   configurations where additional RX clocks are required.
> * Explicitly document the list of clocks and resets for every compatible
>   value; don't miss any out.
> v2:
> * Add an explicit compatible value for the Axis SoC's version of the EQOS
>   IP; this allows the driver to handle any SoC-specific integration quirks
>   that are required, rather than only knowing about the IP block in
>   isolation. This is good general DT practice. The existing value is still
>   documented to support existing DTs.
> * Reworked the list of clocks the binding requires:
>   - Combined "tx" and "phy_ref_clk"; for GMII/RGMII configurations, these
>     are the same thing.
>   - Added extra description to the "rx" and "tx" clocks, to make it clear
>     exactly which HW clock they represent.
>   - Made the new "tx" and "slave_bus" names more prominent than the
>     original "phy_ref_clk" and "apb_pclk". The new names are more generic
>     and should work for any enhanced version of the binding (e.g. to
>     support additional PHY types). New compatible values will hopefully
>     choose to require the new names.
> * Added a couple extra clocks to the list that may need to be supported in
>   future binding revisions.
> * Fixed a typo; "clocks" -> "resets".
> ---
>  .../bindings/net/snps,dwc-qos-ethernet.txt         | 99 +++++++++++++++++++++-
>  1 file changed, 95 insertions(+), 4 deletions(-)
>
> diff --git a/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt b/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt
> index 51f8d2eba8d8..d93f71ce8346 100644
> --- a/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt
> +++ b/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt
> @@ -1,21 +1,111 @@
>  * Synopsys DWC Ethernet QoS IP version 4.10 driver (GMAC)
>
> +This binding supports the Synopsys Designware Ethernet QoS (Quality Of Service)
> +IP block. The IP supports multiple options for bus type, clocking and reset
> +structure, and feature list. Consequently, a number of properties and list
> +entries in properties are marked as optional, or only required in specific HW
> +configurations.
>
>  Required properties:
> -- compatible: Should be "snps,dwc-qos-ethernet-4.10"
> +- compatible: One of:
> +  - "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10"
> +    Represents the IP core when integrated into the Axis ARTPEC-6 SoC.
> +  - "nvidia,tegra186-eqos", "snps,dwc-qos-ethernet-4.10"
> +    Represents the IP core when integrated into the NVIDIA Tegra186 SoC.
> +  - "snps,dwc-qos-ethernet-4.10"
> +    This combination is deprecated. It should be treated as equivalent to
> +    "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10". It is supported to be
> +    compatible with earlier revisions of this binding.
>  - reg: Address and length of the register set for the device
> -- clocks: Phandles to the reference clock and the bus clock
> -- clock-names: Should be "phy_ref_clk" for the reference clock and "apb_pclk"
> -  for the bus clock.
> +- clocks: Phandle and clock specifiers for each entry in clock-names, in the
> +  same order. See ../clock/clock-bindings.txt.
> +- clock-names: May contain any/all of the following depending on the IP
> +  configuration, in any order:
> +  - "tx"
> +    The EQOS transmit path clock. The HW signal name is clk_tx_i.
> +    In some configurations (e.g. GMII/RGMII), this clock also drives the PHY TX
> +    path. In other configurations, other clocks (such as tx_125, rmii) may
> +    drive the PHY TX path.
> +  - "rx"
> +    The EQOS receive path clock. The HW signal name is clk_rx_i.
> +    In some configurations (e.g. GMII/RGMII), this clock is derived from the
> +    PHY's RX clock output. In other configurations, other clocks (such as
> +    rx_125, rmii) may drive the EQOS RX path.
> +    In cases where the PHY clock is directly fed into the EQOS receive path
> +    without intervening logic, the DT need not represent this clock, since it
> +    is assumed to be fully under the control of the PHY device/driver. In
> +    cases where SoC integration adds additional logic to this path, such as a
> +    SW-controlled clock gate, this clock should be represented in DT.
> +  - "slave_bus"
> +    The CPU/slave-bus (CSR) interface clock. This applies to any bus type;
> +    APB, AHB, AXI, etc. The HW signal name is hclk_i (AHB) or clk_csr_i (other
> +    buses).
> +  - "master_bus"
> +    The master bus interface clock. Only required in configurations that use a
> +    separate clock for the master and slave bus interfaces. The HW signal name
> +    is hclk_i (AHB) or aclk_i (AXI).
> +  - "ptp_ref"
> +    The PTP reference clock. The HW signal name is clk_ptp_ref_i.
> +  - "phy_ref_clk"
> +    This clock is deprecated and should not be used by new compatible values.
> +    It is equivalent to "tx".
> +  - "apb_pclk"
> +    This clock is deprecated and should not be used by new compatible values.
> +    It is equivalent to "slave_bus".
> +
> +  Note: Support for additional IP configurations may require adding the
> +  following clocks to this list in the future: clk_rx_125_i, clk_tx_125_i,
> +  clk_pmarx_0_i, clk_pmarx1_i, clk_rmii_i, clk_revmii_rx_i, clk_revmii_tx_i.
> +  Configurations exist where multiple similar clocks are used at once, e.g. all
> +  of clk_rx_125_i, clk_pmarx_0_i, clk_pmarx1_i. For this reason it is best to
> +  extend the binding with a separate clock-names entry for each of those RX
> +  clocks, rather than repurposing the existing "rx" clock-names entry as a
> +  generic/logical clock in a similar fashion to "master_bus" and "slave_bus".
> +  This will allow easy support for configurations that support multiple PHY
> +  interfaces using a mux, and hence need to have explicit control over
> +  specific RX clocks.
> +
> +  The following compatible values require the following set of clocks:
> +  - "nvidia,tegra186-eqos", "snps,dwc-qos-ethernet-4.10":
> +    - "slave_bus"
> +    - "master_bus"
> +    - "rx"
> +    - "tx"
> +    - "ptp_ref"
> +  - "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10":
> +    - "slave_bus"
> +    - "master_bus"
> +    - "tx"
> +    - "ptp_ref"
> +  - "snps,dwc-qos-ethernet-4.10" (deprecated):
> +    - "phy_ref_clk"
> +    - "apb_clk"
>  - interrupt-parent: Should be the phandle for the interrupt controller
>    that services interrupts for this device
>  - interrupts: Should contain the core's combined interrupt signal
>  - phy-mode: See ethernet.txt file in the same directory
> +- resets: Phandle and reset specifiers for each entry in reset-names, in the
> +  same order. See ../reset/reset.txt.
> +- reset-names: May contain any/all of the following depending on the IP
> +  configuration, in any order:
> +  - "eqos". The reset to the entire module. The HW signal name is hreset_n
> +    (AHB) or aresetn_i (AXI).
> +
> +  The following compatible values require the following set of resets:
> +  (the reset properties may be omitted if empty)
> +  - "nvidia,tegra186-eqos", "snps,dwc-qos-ethernet-4.10":
> +    - "eqos".
> +  - "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10":
> +    - None.
> +  - "snps,dwc-qos-ethernet-4.10" (deprecated):
> +    - None.
>
>  Optional properties:
>  - dma-coherent: Present if dma operations are coherent
>  - mac-address: See ethernet.txt in the same directory
>  - local-mac-address: See ethernet.txt in the same directory
> +- phy-reset-gpios: Phandle and specifier for any GPIO used to reset the PHY.
> +  See ../gpio/gpio.txt.
>  - snps,en-lpi: If present it enables use of the AXI low-power interface
>  - snps,write-requests: Number of write requests that the AXI port can issue.
>    It depends on the SoC configuration.
> @@ -52,6 +142,7 @@ ethernet2@40010000 {
>  	reg = <0x40010000 0x4000>;
>  	phy-handle = <&phy2>;
>  	phy-mode = "gmii";
> +	phy-reset-gpios = <&gpioctlr 43 GPIO_ACTIVE_LOW>;
>
>  	snps,en-tx-lpi-clockgating;
>  	snps,en-lpi;
>

Acked-by: Lars Persson <larper@axis.com>

--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Stephen Warren Sept. 8, 2016, 5:49 p.m. UTC | #2
On 09/01/2016 01:02 PM, Stephen Warren wrote:
> From: Stephen Warren <swarren@nvidia.com>
>
> The Synopsys DWC EQoS is a configurable IP block which supports multiple
> options for bus type, clocking and reset structure, and feature list.
> Extend the DT binding to define a "compatible value" for the configuration
> contained in NVIDIA's Tegra186 SoC, and define some new properties and
> list property entries required by that configuration.
>
> Signed-off-by: Stephen Warren <swarren@nvidia.com>
> ---
> v3:
> * Document legacy clock-names entries separately, and make it obvious
>   they're deprecated.
> * Reword the description of the "rx" clock to better describe the HW.
> * Add some extra guidance for future extensions of the binding to cover
>   configurations where additional RX clocks are required.
> * Explicitly document the list of clocks and resets for every compatible
>   value; don't miss any out.

Rob, Mark,

Does this version look good (Lars already acked it)? If so, if you could 
ack it that'd be great; I want to send some U-Boot drivers that use this 
binding, but don't want to do so before I know it's final.

Thanks.
--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Rob Herring Sept. 12, 2016, 1:38 p.m. UTC | #3
On Thu, Sep 08, 2016 at 11:49:31AM -0600, Stephen Warren wrote:
> On 09/01/2016 01:02 PM, Stephen Warren wrote:
> >From: Stephen Warren <swarren@nvidia.com>
> >
> >The Synopsys DWC EQoS is a configurable IP block which supports multiple
> >options for bus type, clocking and reset structure, and feature list.
> >Extend the DT binding to define a "compatible value" for the configuration
> >contained in NVIDIA's Tegra186 SoC, and define some new properties and
> >list property entries required by that configuration.
> >
> >Signed-off-by: Stephen Warren <swarren@nvidia.com>
> >---
> >v3:
> >* Document legacy clock-names entries separately, and make it obvious
> >  they're deprecated.
> >* Reword the description of the "rx" clock to better describe the HW.
> >* Add some extra guidance for future extensions of the binding to cover
> >  configurations where additional RX clocks are required.
> >* Explicitly document the list of clocks and resets for every compatible
> >  value; don't miss any out.
> 
> Rob, Mark,
> 
> Does this version look good (Lars already acked it)? If so, if you could ack
> it that'd be great; I want to send some U-Boot drivers that use this
> binding, but don't want to do so before I know it's final.

Applied.

Rob
--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt b/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt
index 51f8d2eba8d8..d93f71ce8346 100644
--- a/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt
+++ b/Documentation/devicetree/bindings/net/snps,dwc-qos-ethernet.txt
@@ -1,21 +1,111 @@ 
 * Synopsys DWC Ethernet QoS IP version 4.10 driver (GMAC)
 
+This binding supports the Synopsys Designware Ethernet QoS (Quality Of Service)
+IP block. The IP supports multiple options for bus type, clocking and reset
+structure, and feature list. Consequently, a number of properties and list
+entries in properties are marked as optional, or only required in specific HW
+configurations.
 
 Required properties:
-- compatible: Should be "snps,dwc-qos-ethernet-4.10"
+- compatible: One of:
+  - "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10"
+    Represents the IP core when integrated into the Axis ARTPEC-6 SoC.
+  - "nvidia,tegra186-eqos", "snps,dwc-qos-ethernet-4.10"
+    Represents the IP core when integrated into the NVIDIA Tegra186 SoC.
+  - "snps,dwc-qos-ethernet-4.10"
+    This combination is deprecated. It should be treated as equivalent to
+    "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10". It is supported to be
+    compatible with earlier revisions of this binding.
 - reg: Address and length of the register set for the device
-- clocks: Phandles to the reference clock and the bus clock
-- clock-names: Should be "phy_ref_clk" for the reference clock and "apb_pclk"
-  for the bus clock.
+- clocks: Phandle and clock specifiers for each entry in clock-names, in the
+  same order. See ../clock/clock-bindings.txt.
+- clock-names: May contain any/all of the following depending on the IP
+  configuration, in any order:
+  - "tx"
+    The EQOS transmit path clock. The HW signal name is clk_tx_i.
+    In some configurations (e.g. GMII/RGMII), this clock also drives the PHY TX
+    path. In other configurations, other clocks (such as tx_125, rmii) may
+    drive the PHY TX path.
+  - "rx"
+    The EQOS receive path clock. The HW signal name is clk_rx_i.
+    In some configurations (e.g. GMII/RGMII), this clock is derived from the
+    PHY's RX clock output. In other configurations, other clocks (such as
+    rx_125, rmii) may drive the EQOS RX path.
+    In cases where the PHY clock is directly fed into the EQOS receive path
+    without intervening logic, the DT need not represent this clock, since it
+    is assumed to be fully under the control of the PHY device/driver. In
+    cases where SoC integration adds additional logic to this path, such as a
+    SW-controlled clock gate, this clock should be represented in DT.
+  - "slave_bus"
+    The CPU/slave-bus (CSR) interface clock. This applies to any bus type;
+    APB, AHB, AXI, etc. The HW signal name is hclk_i (AHB) or clk_csr_i (other
+    buses).
+  - "master_bus"
+    The master bus interface clock. Only required in configurations that use a
+    separate clock for the master and slave bus interfaces. The HW signal name
+    is hclk_i (AHB) or aclk_i (AXI).
+  - "ptp_ref"
+    The PTP reference clock. The HW signal name is clk_ptp_ref_i.
+  - "phy_ref_clk"
+    This clock is deprecated and should not be used by new compatible values.
+    It is equivalent to "tx".
+  - "apb_pclk"
+    This clock is deprecated and should not be used by new compatible values.
+    It is equivalent to "slave_bus".
+
+  Note: Support for additional IP configurations may require adding the
+  following clocks to this list in the future: clk_rx_125_i, clk_tx_125_i,
+  clk_pmarx_0_i, clk_pmarx1_i, clk_rmii_i, clk_revmii_rx_i, clk_revmii_tx_i.
+  Configurations exist where multiple similar clocks are used at once, e.g. all
+  of clk_rx_125_i, clk_pmarx_0_i, clk_pmarx1_i. For this reason it is best to
+  extend the binding with a separate clock-names entry for each of those RX
+  clocks, rather than repurposing the existing "rx" clock-names entry as a
+  generic/logical clock in a similar fashion to "master_bus" and "slave_bus".
+  This will allow easy support for configurations that support multiple PHY
+  interfaces using a mux, and hence need to have explicit control over
+  specific RX clocks.
+
+  The following compatible values require the following set of clocks:
+  - "nvidia,tegra186-eqos", "snps,dwc-qos-ethernet-4.10":
+    - "slave_bus"
+    - "master_bus"
+    - "rx"
+    - "tx"
+    - "ptp_ref"
+  - "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10":
+    - "slave_bus"
+    - "master_bus"
+    - "tx"
+    - "ptp_ref"
+  - "snps,dwc-qos-ethernet-4.10" (deprecated):
+    - "phy_ref_clk"
+    - "apb_clk"
 - interrupt-parent: Should be the phandle for the interrupt controller
   that services interrupts for this device
 - interrupts: Should contain the core's combined interrupt signal
 - phy-mode: See ethernet.txt file in the same directory
+- resets: Phandle and reset specifiers for each entry in reset-names, in the
+  same order. See ../reset/reset.txt.
+- reset-names: May contain any/all of the following depending on the IP
+  configuration, in any order:
+  - "eqos". The reset to the entire module. The HW signal name is hreset_n
+    (AHB) or aresetn_i (AXI).
+
+  The following compatible values require the following set of resets:
+  (the reset properties may be omitted if empty)
+  - "nvidia,tegra186-eqos", "snps,dwc-qos-ethernet-4.10":
+    - "eqos".
+  - "axis,artpec6-eqos", "snps,dwc-qos-ethernet-4.10":
+    - None.
+  - "snps,dwc-qos-ethernet-4.10" (deprecated):
+    - None.
 
 Optional properties:
 - dma-coherent: Present if dma operations are coherent
 - mac-address: See ethernet.txt in the same directory
 - local-mac-address: See ethernet.txt in the same directory
+- phy-reset-gpios: Phandle and specifier for any GPIO used to reset the PHY.
+  See ../gpio/gpio.txt.
 - snps,en-lpi: If present it enables use of the AXI low-power interface
 - snps,write-requests: Number of write requests that the AXI port can issue.
   It depends on the SoC configuration.
@@ -52,6 +142,7 @@  ethernet2@40010000 {
 	reg = <0x40010000 0x4000>;
 	phy-handle = <&phy2>;
 	phy-mode = "gmii";
+	phy-reset-gpios = <&gpioctlr 43 GPIO_ACTIVE_LOW>;
 
 	snps,en-tx-lpi-clockgating;
 	snps,en-lpi;